R01UH0336EJ0102 Rev.1.02
Page 1426 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 24 Peripheral Interconnection (PIC)
(2)
Encoder Capture by TAUB0TINTm
Encoder capture can be operated after a TAUB0TINTm (TAUB0-CHm interrupt
signal) is selected and connected it to ENCA0.
An operation example of this function with TAUB0TINTm trigger for ENCA0 is
described below.
Figure 24-23
Operation example of encoder capture with TAUB0TINTm trigger.
<1> TAUB0CNTm, TAUB0CNTm-1 and ENCA0 start count operation at the
same time by a simultaneous start trigger.
<2> When TAUB0TINTm (TAUB0-CHm interrupt request signal) is selected as
ENCA0I1 (ENCA0 capture trigger 1 signal), ENCA0 caption counter value
to a capture register by TAUB0TINTm input.
<3> If the input is not TAUB0TINTm but TAUB0TINTm-1 (TAUB0-CHm
interrupt request signal), the capture of ENCA0 is not operated.
Timers simultaneous start
Count enable
FFFF
H
FFFF
H
FFFF
H
0000
H
0000
H
0000
H
TAUB0CNTm
TAUB0CNTm-1
TAUB0TINTm
TAUB0TINTm-1
ENCAkl1
ENCAkCNT
a
d
a
b
b
c
c
ENCAkCCR1
<1>
<2>
<3>