R01UH0336EJ0102 Rev.1.02
Page 470 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 13 Timer Array Unit B (TAUB)
(4)
Register settings
(a)
TAUBnCMORm
(b)
TAUBnCMURm
(c)
Channel output mode
TAUBnTOE.TAUBnTOEm is set to 0 because the channel output mode is not
used with this function. However, this mode can be used in independent
channel output mode controlled by software.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
TAUBnCKS
[1:0]
TAUBnCCS
[1:0]
TAUB
nMAS
TAUBnSTS[2:0]
TAUBnCOS
[1:0]
-
TAUBnMD[4:1]
TAUBn
MD0
Table 13-37
TAUBnCMORm Settings for TAUBnTTINm Input Period Count Detection
Function
Bit Name
Setting
TAUBnCKS[1:0]
00: Operation clock = CK0
01: Operation clock = CK1
10: Operation clock = CK2
11: Operation clock = CK3
TAUBnCCS[1:0]
00: Uses an operation clock as a count clock.
TAUBnMAS
0: Unused. Set to 0.
TAUBnSTS[2:0]
010: Valid edge of the TAUBnTTINm input signal is used as
an external start trigger and the reverse edge as a stop
trigge.
TAUBnCOS[1:0]
01: Set this value.
TAUBnMD[4:1]
1101: Capture and gate count mode
TAUBnMD0
0: Disables a start trigger during operation.
7
6
5
4
3
2
1
0
-
TAUBnTIS[1:0]
Table 13-38
TAUBnCMURm Settings for TAUBnTTINm Input Period Count Detection
Function
Bit Name
Setting
TAUBnTIS[1:0]
10: Detection of falling and rising edges (Low width
measurement)
11: Detection of falling and rising edges (High width
measurement)
Содержание V850 Series
Страница 1556: ...V850E2 PG4 L R01UH0336EJ0102 Back Cover ...