Optional Bin Pressure Sensor Calibration
Touch the Pressure Calibration button to access the Pressure Cal screen.
Pressure 1 and 2 Cal.
The Pressure Cal screen displays the current calibration setting for each pressure
transducer connected to the product. Touch the Pressure Cal button and use the on-screen keypad to enter a
different target pressure for the bin.
Threshold.
The threshold setting is the lowest acceptable pressure detected in the air seeder system before
the field computer displays an alert.
Pressure 1 and 2 Display.
The current pressures detected by the pressure transducers on each product are
displayed in the bottom half of the Pressure Cal screen.
Enable Bin Pressure Alarm.
Select the bin pressure alarm option to allow the field computer to sound an
audible alarm if any of the bin pressures fall below the set threshold value.
Fan Calibration
Touch the “Fan Cal” button to access the Fan Calibration Settings screen.
Fan Cal.
Touch the Fan Cal button and use the on-screen keypad to enter the number of pulses detected by
the fan speed sensor per revolution of the fan.
Содержание Envizio Pro
Страница 3: ......
Страница 13: ...Table of Contents x Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 32: ...3 P N 016 0171 493 Rev I 17 Installation FIGURE 1 Envizio Pro Kit Contents Drawing Number 054 2040 004 ...
Страница 51: ...Chapter 4 36 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 65: ...Chapter 5 50 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 193: ...Chapter 9 178 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 197: ...Chapter 10 182 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 229: ...Appendix D 214 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 285: ...Index 270 Envizio Pro and Envizio Pro II Installation and Operation Manual ...