5
P/N 016-0171-493 Rev. I
47
Startup, Initial Setup, and Setup Wizards
should be refined for the individual control valves installed on each specific machine. See Appendix A,
Calculating the Calibration Values
, for instructions on refining the valve cal value.
Note:
The Valve Advance button is only available if the assigned product node has software version 1.50
or higher. Refer to the Valve Advance (Standard or Fast Valve) section on page 105 for
information about the Valve Advance feature.
The Modify PWM Settings button will only be displayed if PWM or PWM Close is selected as the
valve type. Refer to the Modify PWM Settings (PWM or PWM Close Valve) section on page 106
for information on these settings.
8.
Touch the Next
icon. The field computer will display a
prompt for one of the following:
•
Meter cal for the flow meter used to measure the first
control channel 1 (liquid products). The flow meter
calibration number can be found on the tag attached
to the flow meter. Refer to the
page 191 for details on adjusting the meter cal.
Note:
Copy the information from the tag for future reference
as the tags may fade or be lost during operation.
•
Density of product 1 (granular products). Refer to
section on page 200 for details on the product density required for the control
system.
•
Spinner cal (spinner control nodes). Refer to the
information on calculating the spinner cal value necessary for spinner control.
Use the on-screen keypad to enter the correct value.
9.
Touch the Next
icon. The field computer will display a
prompt for one of the following:
•
Rate cal (liquid and granular products). Review
Appendix A,
Calculating the Calibration Values
, for
information on calculating the rate calibration value
for a specific application type.
•
RPM cal (spinner control nodes). Refer to the
section on page 201 for information on
the necessary RPM cal to control spinner speed
during field operations.
Use the on-screen keypad to enter the target rate or spinner
RPM for product 1.
10.
If a granular application control type is selected, the field computer will prompt the operator for the Spreader
Constant. Refer to the
section on page 199 for details on calculating and adjusting the
spreader constant value for the specific application equipment.
Содержание Envizio Pro
Страница 3: ......
Страница 13: ...Table of Contents x Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 32: ...3 P N 016 0171 493 Rev I 17 Installation FIGURE 1 Envizio Pro Kit Contents Drawing Number 054 2040 004 ...
Страница 51: ...Chapter 4 36 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 65: ...Chapter 5 50 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 193: ...Chapter 9 178 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 197: ...Chapter 10 182 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 229: ...Appendix D 214 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 285: ...Index 270 Envizio Pro and Envizio Pro II Installation and Operation Manual ...