P/N 016-0171-493 Rev. I
243
Meter Cal.
Press the Enter key on the meter cal option to edit the current meter cal value. The meter cal value
is the number of counts the metering roller sensor will detect per revolution of the metering roller.
Use the INC or DEC keys to adjust the meter cal value and press the Enter key to set the meter cal value.
Note:
It is recommended to enter a meter cal of 60 when using the Envizio Pro for the hydraulic drive
system.
Cal Weight.
Press the Enter key on the cal weight option and use the INC or DEC keys to adjust the set cal
weight value. The cal weight value to set the cal weight sets the weight of product applied per revolution of
the metering roller.
Refer to
section on page 240 and the
section on page 241 for details on using the
remote tank console to calculate the cal weight value.
4.
Press the Next key on the cal weight option to advance to the next settings screen.
Note:
The second settings screen is only accessible if the valve type for the selected product bin is set to
PWM or PWM close. Refer to the Valve section on page 103 for detailed information on valve type
selections.
The following settings are displayed on the second settings screen:
Note:
Use the Next or Prev keys to move the cursor between the screen options. Pressing the Prev key
on the PWM frequency option will return to the previous settings screen. Press the Next key on the
min PW option to exit the settings menu and return to the bin calibration screen.
PW Freq.
Press the Enter key and use the INC or DEC keys to set the coil frequency of the PWM valve. The
default value for hydraulic drive systems is 122 Hz.
Min PW.
Press the
E
nter key and use the INC or DEC keys to set the minimum desired RPM or hydraulic
output (zero point or shutoff point) for a Pulse Width Modulated (PWM) control valve.
Max PW.
Press the Enter key and use the INC or DEC keys to set the maximum desired RPM or hydraulic
output (zero point or shutoff point) for a Pulse Width Modulated (PWM) control valve.
Note:
Refer to PWM Calibration Screen section on page 107 for details on using the calibration
assistance to calculate the Min and Max PW values.
Содержание Envizio Pro
Страница 3: ......
Страница 13: ...Table of Contents x Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 32: ...3 P N 016 0171 493 Rev I 17 Installation FIGURE 1 Envizio Pro Kit Contents Drawing Number 054 2040 004 ...
Страница 51: ...Chapter 4 36 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 65: ...Chapter 5 50 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 193: ...Chapter 9 178 Envizio Pro and Envizio Pro II Installation and Operation Manual ...