P/N 016-0171-493 Rev. I
117
Tools Menu
7
Bin Alarm
In any of the granular modes, a bin alarm option is displayed on the Alarm Settings screen. Enable the Bin
Alarm if a bin level sensor is connected to the control system. When the sensor detects a low level in the bin,
the field computer displays the alarms window to alert the operator of the condition.
Vacuum Alarm
The vacuum alarm is available when a CAN motor control or injection node is detected on the CANbus. Enable
this alarm to display an alert if the injection system begins running in a vacuum state.
CAN Audible Alarm
Select the CAN Audible Alarm to enable the audible alarm tone for the configured settings on this screen. If
any of the following settings are encountered, the field computer plays an audible tone to warn the operator of
the condition.
Flow Error Cal (CAN Motor Control)
If a CAN motor control node for an injection pump is connected to the CANbus. the Alarm Settings screen will
display the Flow Cal alarm feature. This alarm may be used to indicate that the chemical tank is empty or the
pump is unable to prime or inject product.
Enter a value between 0 and 100 for the percentage of error allowed between the flow switch and pump
encoder before a flow alarm will be displayed. For example, set this value to 100 to disable the flow error cal
alarm or 0 to display an error any time the flow switch and pump encoder do not match. The default value for
the flow error cal alarm is 50.
Note:
The Flow Error Cal is replaced with the FER (Flow to Encoder Ratio) value when operating a
Raven Sidekick Pro™. Refer to the Sidekick Pro Installation and Operation Manual for more
information about operation with the Envizio Pro field computers.
NH3 Configuration
Note:
The NH3 configuration value will only be available when the field computer is configured for
interfacing with a Raven anhydrous ammonia control system such as AccuFlow™ or AccuFlow
HP™ Plus. Refer to Application Type section on page 100 for additional assistance with the
application type settings.
Enter the following values to set the system features available with the AccuFlow system:
Value
Remote Proximity Sensor
Section Feedback
3
Enabled
Disabled
4
Disabled
Disabled
5
Enabled
Enabled
6 (Default)
Disabled
Enabled
Содержание Envizio Pro
Страница 3: ......
Страница 13: ...Table of Contents x Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 32: ...3 P N 016 0171 493 Rev I 17 Installation FIGURE 1 Envizio Pro Kit Contents Drawing Number 054 2040 004 ...
Страница 51: ...Chapter 4 36 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 65: ...Chapter 5 50 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 193: ...Chapter 9 178 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 197: ...Chapter 10 182 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 229: ...Appendix D 214 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 285: ...Index 270 Envizio Pro and Envizio Pro II Installation and Operation Manual ...