P/N 016-0171-493 Rev. I
201
Calculating the Calibration Values
Spinner RPM
For spinner box machines, use a product control node capable of controlling spinner speed.
Valve Type
Select the valve type currently used on the machine in which the field computer is installed.
Application
Select ‘Spinner’ as the application type. If spinner does not show up on the application rate, check that a CAN
control node capable of controlling spinner applications is connected to the CANbus. Check the CAN control
node and install a node that is capable of spinner control.
Meter Cal
The machine should be configured with a magnetic pickup coil mounted near the bolt heads on the spinner.
Calculate the meter cal by multiplying the number of pulses (bolt heads) per revolution by 10.
For Example:
If the number of pulses per revolution is 4:
then the value for the meter cal would be 40.
Spreader Constant
The spreader constant should be set to 0.
Rate Cal
The rate cal should be set to the desired RPM of the spinner.
MeterCal
N
10
×
=
4
10
×
40
=
Содержание Envizio Pro
Страница 3: ......
Страница 13: ...Table of Contents x Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 32: ...3 P N 016 0171 493 Rev I 17 Installation FIGURE 1 Envizio Pro Kit Contents Drawing Number 054 2040 004 ...
Страница 51: ...Chapter 4 36 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 65: ...Chapter 5 50 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 193: ...Chapter 9 178 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 197: ...Chapter 10 182 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 229: ...Appendix D 214 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Страница 285: ...Index 270 Envizio Pro and Envizio Pro II Installation and Operation Manual ...