Appendix K
Error Messages
549
Corrective Action
Error Message
O
[Object Name] – % value is out of limit.
Default values restored for 100%, 0%,
and –100%.
Correct the screen data or the program at
the host so that a value of up to 8 digits
will be sufficient for the 100% value, 0%
value and –100% value in the bar graph.
[Object Name] has exceeded the maxi-
mum number of characters.
Set the character string within the limit.
[Object name] refers to invalid numeral
table entry. The referenced table entry is
reset to entry 0.
Correct the table entry number to a num-
ber within the valid range. If the table entry
number is specified in a program, correct
the program also.
[Object Name] – Invalid PLC address. It
is reset to default.
Reset the word number to a number of up
to 4 digits. If this PC (PLC) address is re-
ferred to from the program, it is necessary
to correct the program accordingly.
[Object Name] – inverse attribute not
supported. Foreground and Background
colors interchanged.
Since foreground color and background
color are automatically interchanged, no
special correction is required (display at-
tribute is set to default (standard).).
Overlapping screen has more than 1
child screen containing Thumbwheel/Nu-
meral/String Input elements.
Overlapping screens do not allow the set-
ting of multiple input functions. Correct the
child screens.
P
Please make sure this parent screen
have at least 2 children.
Select the parent screen, then right click
the mouse and select [Modify]. Insert at
least 2 child screens for the parent screen.
S
Sampling cycle less than the minimum
value. Minimum value is restored.
Since there are no problems in actual op-
eration, correction is not necessary.
Sampling cycle not multiple of 5. Value
rounded off to nearest multiple of 5.
Since there are no problems in actual op-
eration, correction is not necessary.
Screen is empty, downloading may not
be possible.
Create the data in the empty screen or de-
lete the empty screen.
Some objects exceed library size in code
FA20. The objects will not be down-
loaded to PT hardware.
Reduce the size of elements exceeding
the library size using the library editor, or
set a larger library size.
String Table: Table Entry XXX has invalid
component code. It has been converted
from XXXX to YYYY.
Delete the code from the character string
and make corrections so that an equiva-
lent display can be obtained by displaying
and grouping the character string and the
fixed display image/library data.
T
The associated touch switches of the
alarm has been discarded and compo-
nent touch switches have been created.
Correct the position of the control touch
switches as needed. If a control touch
switch is not necessary, cancel the check
for the control touch switch in the alarm
list/history properties. (With alarm touch
switches for NT31, NT31C, NT631, and
NT631, it is not possible to change the
size and label.)
The child screen XXX containing Numer-
al/String Input element(s) does not have
the same key attribute as the overlapping
screen.
In the screen properties, set the same
[Keypad] attribute both for the parent and
child screens.
Содержание NT - SUPPORT TOOL FOR WINDOWS V4
Страница 1: ...Support Tool for Windows Ver 4 Cat No V061 E1 05 NT series OPERATION MANUAL...
Страница 2: ...NT series Support Tool for Windows Ver 4 j Operation Manual Revised May 2007...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 353: ...8 2 Section Library Editor 341 Double clicking the control menu box of the library editor Control menu box...