6-3
Section
Alarm
167
With these models above, up to 40 characters can be displayed regardless of
the display method etc.
Display Line Qty:
Specify the number of messages to be displayed.
Max. 7 lines:
NT21
Max. 12 lines:
NT30, NT30C, NT31, NT31C
Max. 16 lines:
NT620S
Max. 24 lines:
NT620C, NT625C, NT631, NT631C
Scale:
Specify the character size of the message to be displayed.
1
1 (Equal), 1
2 (High), 2
1 (Wide), 2
2, 3
3, 4
4, 8
8
Smoothing: Specify if smoothing processing is executed for the message to
be displayed.
Line Scroll Touch Switch:
Set if a touch switch is set for scrolling messages
line by line. Only for NT31, NT31C, NT631, and
NT631C
Page Scroll Touch Switch: Set if a touch switch is set for scrolling messages
page by page. Only for NT31, NT31C, NT631, and
NT631C
Color
Frame:
Specify the color used for the frame of an alarm list.
Background
ON:
Specify the background color of the selected message dis-
play field.
OFF:
Specify the background color of the message display fields
that are not selected.
Image & Library
Display of Image Lib:
Specify if the image/library data is displayed.
Color
Specification of color is valid only when the image data of 2-color mode is dis-
played by a color type PT.
Foreground:
Specify the display color of image data.
Background:
Specify the background color of the image data display
area.
Reference: With NT30, NT30C, NT620S, NT620C, and NT625C, a dialog box is displayed to
set if line scroll touch switch and page scroll touch switch are used.
With NT31, NT31C, NT631, and NT631C, whether or not the line scroll touch
switch and page scroll touch switch are used is determined by the setting for the
use of control touch switches in the alarm list/history properties.
Settings
History Info:
Specify whether or not an alarm message is displayed with date/time of occur-
rence or frequency of occurrence. If a check mark is set for this item, the date/
time of alarm occurrence is displayed with an alarm message for display in
order of occurrence, or the frequency of occurrence is displayed with an alarm
Содержание NT - SUPPORT TOOL FOR WINDOWS V4
Страница 1: ...Support Tool for Windows Ver 4 Cat No V061 E1 05 NT series OPERATION MANUAL...
Страница 2: ...NT series Support Tool for Windows Ver 4 j Operation Manual Revised May 2007...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 353: ...8 2 Section Library Editor 341 Double clicking the control menu box of the library editor Control menu box...