Appendix A
Data Conversion
468
Status before
Conversion
Status after
Conversion
Error Message
Corrective Action
With a conventional
model, a window/
keyboard screen is
specified as a child
screen.
With a new model,
a window/keyboard
screen is removed
from child screens.
The screen no. XXX
of type YYY is not
supported as a
child, so the parent-
child association is
discarded.
Copy the contents of the
window/keyboard
screen to a standard
screen and specify that
standard screen as a
child screen. (Refer to
5-3-2.Overlapping
Screens)
Correction related to number of window/keyboard screens to be opened
When a window/keyboard screen is converted, conversion is executed as shown
below due to differences in number of window/keyboard screens that can be dis-
played at the same time.
Difference
New models (NT21, NT31/631-V1 and above):
Up to three window/keyboard screens can be opened
at the same time. (1 Global Window and 2 Local Win-
dows)
With a screen attribute, up to two local windows can
be specified as pop-up windows to be displayed
when the screen is opened.
With a touch switch (cursor move and input key-win-
dow/keyboard function), specification of local win-
dow 1 or 2 is possible.
Conventional models, New models (NT31/631):
Only one window/keyboard screen can be opened.
(Local window 1 (keyboard) only)
With a screen attribute, only one window can be spe-
cified as a pop-up window to be displayed when the
screen is opened.
With a touch switch (cursor move and input key-win-
dow/keyboard function), specification of only local
window 1 (keyboard) is possible.
Conversion result, error message and corrective action
Status before
Conversion
Status after
Conversion
Error Message
Corrective Action
With a new model
with “-V1” and
above, local window
2 is specified for the
attribute of touch
switch. And the
touch switch is reg-
istered to the sym-
bol manager.
Minimum value is
restored for window/
keyboard screen
number.
Input Key-Window/
Keyboard screen
number is not within
the valid range.
Minimum value re-
stored.
Correct the screen data
so that the local window
1 includes all the re-
quired elements.
Correction related to display range of window/keyboard screens
When a window/keyboard screen is converted, conversion is executed as shown
below due to differences in the window/keyboard screen display range between
a conventional and a new model.
Difference:
New models:
A window/keyboard screen can be specified only in
the range that fits the touch switch grids.
Содержание NT - SUPPORT TOOL FOR WINDOWS V4
Страница 1: ...Support Tool for Windows Ver 4 Cat No V061 E1 05 NT series OPERATION MANUAL...
Страница 2: ...NT series Support Tool for Windows Ver 4 j Operation Manual Revised May 2007...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 353: ...8 2 Section Library Editor 341 Double clicking the control menu box of the library editor Control menu box...