Appendix A
Data Conversion
467
Status before
Conversion
Status after
Conversion
Error Message
Corrective Action
With a new model,
word addresses are
within four digits.
With a conventional
model, word
addresses remain
as they were.
––
––
With a new model,
the word address is
five digits.
The word address is
reset.
Invalid PC (PLC)
address. It is reset
to default.
Reset the word address
to a number of four or
less digits. If this PC
(PLC) address is re-
ferred to from the pro-
gram, it is necessary to
correct the program ac-
cordingly. (Refer to
6-1-10 Setting Proper-
ties.)
With a new model
with V2/V3, the ac-
cessible CS/CJ-se-
ries area is speci-
fied.
The word address is
reset.
Invalid PL (PLC) ad-
dress. It is reset to
default.
Reset the word address
to an accessible area. If
this PLC address is re-
ferred to using program-
ming, also make correc-
tions in accordance with
the programming. (Refer
to Word setting for an
element in 6-1-10 Set-
ting Properties.
Correction related to continuous screens
When the data of a conventional model is converted into data for a new model, an
error may occur due to differences in the handling of continuous screens be-
tween conventional models and new models.
Difference
New models:
Continuous screens cannot be used.
Conventional models:
Continuous screens can be used.
Conversion result, error message and corrective action
Status before
Conversion
Status after
Conversion
Error Message
Corrective Action
With conventional
models, continuous
screens are used.
The parent screen
of the continuous
screens is deleted.
The screen no.
XXXX was a Con-
tinuous Parent
Screen that is not
supported in this
model. It is dis-
carded.
Use a touch switch to
switch screens. If the
program is created to
display the parent
screen of continuous
screens, correct the pro-
gram so that the first
child screen is dis-
played. (Refer to 6-8-2
Switch Screen Touch
Switch.)
Correction related to overlapping screens
When overlapping screens are converted, an error may occur due to differences
in the handling of overlapping screens between conventional models and new
models.
Difference
New models:
A window/keyboard screen cannot be specified as a
child screen.
Conventional models:
A window/keyboard screen can be specified as a
child screen.
Conversion result, error message and corrective action
Содержание NT - SUPPORT TOOL FOR WINDOWS V4