Appendix A
Data Conversion
479
Conversion result, error message and corrective action
Status before
Conversion
Status after
Conversion
Error Message
Corrective Action
With a new model,
a numeral setting
input field (or a
thumbwheel switch)
for which a numeric
value exceeding 8
digits is input is reg-
istered to the sym-
bol manager.
With a conventional
model, a numeral
setting input field (or
a thumbwheel
switch) of greater
than 8 digits is dis-
carded.
[E]
[Numeral Input] –
Total number of in-
teger and decimal
exceeds limit. It is
discarded.
Create a new numeral
setting input field
(thumbwheel switch).
Correct the screen data
or the program in the
host so that a constant
of up to 8 digits suffices.
(Refer to 6-4-1 Numeral
Input , 6-4-3 Thumb-
wheel Switch.)
Correction related the reference memory table entries for numeral input
In the conversion of the data between a conventional and a new model, conver-
sion is executed in the manner shown below due to differences in the numeral
memory table entries that can be referred to.
Difference
New models:
For numeral memory table entries No. 247 to No.
253, reference is not possible for numeral input/
thumbwheel switch.
Conventional models:
For numeral memory table entries No. 247 to No.
253, reference is possible for numeral input/thumb-
wheel switch. (Display only)
Conversion result, error message and corrective action
Status before
Conversion
Status after
Conversion
Error Message
Corrective Action
With a conventional
model, a numeral
setting input field (or
a thumbwheel
switch) for which a
numeral memory
table in the range
No. 247 to No. 253
is referred to is reg-
istered to the sym-
bol manager.
With a new model,
the reference nu-
meral memory table
No. is corrected to
0.
Thumbwheel switch
refers to reserved
numeral table entry.
The referenced
table entry is reset
to 0.
Make corrections so that
the contents of a numer-
al memory table in the
range No. 247 to No.
253 are displayed in a
numeral display. (Refer
to 6-6 Numeral Display.)
Correction related to an interlock function of a touch switch, numeral/string input, or thumbwheel
In the conversion of the data between a V2/V3 model and a non-V2/V3 model/
conventional model, conversion is executed in the manner shown below due to
an interlock function, that has been added to V2/V3 models.
Difference
V2/V3 models: Operations/Inputs can be enabled/disabled according to the
status of the host bit (interlock bit).
Conventional models, non-V2/V3 models: Interlock bit can not be set.
Conversion result, error message and corrective action
Status before
Conversion
Status after
Conversion
Error Message
Corrective Action
With V2/V3 models,
an object allocated
an interlock function
is registered in the
symbol manager.
With non-V2/V3
models/convention-
al models, an inter-
lock bit setting will
be discarded.
Interlock not sup-
ported. Interlock
setting will be dis-
carded.
Screen switching, nu-
meral/string input at PT
side can be enabled/dis-
abled using the PT con-
trol bit in PT control area
also. Modify the pro-
gram according to the
setting.
Содержание NT - SUPPORT TOOL FOR WINDOWS V4
Страница 1: ...Support Tool for Windows Ver 4 Cat No V061 E1 05 NT series OPERATION MANUAL...
Страница 2: ...NT series Support Tool for Windows Ver 4 j Operation Manual Revised May 2007...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 353: ...8 2 Section Library Editor 341 Double clicking the control menu box of the library editor Control menu box...