11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 93
(2) Connection example
MCCB
L1
L2
L3
L11
L21
Servo amplifier
1
2
3
4
5
6
E
(Note 2)
Surge protector
(Note 1)
Power supply
1
2
3
MC
EMC filter
Note 1. Refer to section 1.3 for the power supply specifications.
2. The example is when a surge protector is connected.
(3) Dimensions
(a) EMC filter
HF3010A-UN
[Unit: mm]
32 ± 2
85 ± 2
110 ± 4
258 ± 4
273 ± 2
288 ± 4
300 ± 5
M4
IN
3-M4
65 ± 4
Approx. 41
4-5.5 × 7
3-M4