4. STARTUP
4 - 13
(2) Indication list
Indication Status
Description
Initializing
System check in progress
A b
Initializing
Power of the servo amplifier was switched on at the condition that the power of the
servo system controller is off.
The control axis No. set to the auxiliary axis number setting switches (SW2-3 and
SW2-4) and the axis selection rotary switch (SW1) do not match the one set to the
servo system controller.
A servo amplifier malfunctioned, or communication error occurred with the servo
system controller or the previous axis servo amplifier. In this case, the indication
changes as follows:
"Ab", "AC", "Ad", and "Ab"
The servo system controller is malfunctioning.
A b .
Initializing
During initial setting for communication specifications
A C
Initializing
Initial setting for communication specifications completed, and then it synchronized
with servo system controller.
A d
Initializing
During initial parameter setting communication with servo system controller
A E
Initializing
During the servo motor/encoder information and telecommunication with servo
system controller
A F
Initializing
During initial signal data communication with servo system controller
A H
Initializing
completion
The process for initial data communication with the servo system controller is
completed.
A A
Initializing
standby
The power supply of servo system controller is turned off during the power supply of
servo amplifier is on.
(Note 1) b # #
Ready-off
The ready-off signal from the servo system controller was received.
(Note 1) d # #
Servo-on
The ready-off signal from the servo system controller was received.
(Note 1) C # #
Servo-off
The ready-off signal from the servo system controller was received.
(Note 2)
* *
*
Alarm and warning
The alarm No. and the warning No. that occurred is displayed. (Refer to section 8.
(Note 4))
8 8
8
CPU error
CPU watchdog error has occurred.
(Note 1)
# #
b
.
(Note 3)
Test operation mode
JOG operation, positioning operation, program operation, output signal (DO) forced
output, or motor-less operation was set.
# #
d
.
# #
C
.
Note 1. The meanings of ## are listed below.
## Description
01
to
64
Axis No. 1
to
Axis No. 64
2. ** indicates the alarm No. and the warning No.
3. Requires the MR Configurator2.
4. Only a list of alarms and warnings is listed in chapter 8. Refer to "MELSERVO-J4 Servo Amplifier Instruction Manual
(Troubleshooting)" for details of alarms and warnings.
Содержание MR-J4-100B(-RJ)
Страница 17: ...8 MEMO ...
Страница 143: ...4 STARTUP 4 20 MEMO ...
Страница 199: ...5 PARAMETERS 5 56 MEMO ...
Страница 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Страница 303: ...9 DIMENSIONS 9 22 MEMO ...
Страница 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Страница 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Страница 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Страница 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Страница 653: ...APPENDIX App 40 This certificate is valid until 2017 02 28 After March 2017 use certificate shown on the previous page ...
Страница 654: ...APPENDIX App 41 ...