5. PARAMETERS
5 - 44
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
PD11
*DIF
Input filter setting
Select the input filter.
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x
Input signal filter selection
Refer to the servo system controller instruction manual for the
setting.
If external input signal causes chattering due to noise, etc., input
filter is used to suppress it.
0: None
1: 0.888 [ms]
2: 1.777 [ms]
3: 2.666 [ms]
4: 3.555 [ms]
4h
_ _ x _
For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PD12
*DOP1 Function selection D-1
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x
For manufacturer setting
0h
_ _ x _
0h
_ x _ _
0h
x _ _ _
Servo motor or linear servo motor thermistor enabled/disabled
selection
0: Enabled
1: Disabled
For servo motors or linear servo motor without thermistor, the
setting will be disabled.
This parameter setting is used with servo amplifier with software
version A5 or later.
0h
PD13
*DOP2 Function selection D-2
Select the INP (In-position) on condition.
This parameter is supported with software version B4 or later.
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x
For manufacturer setting
0h
_ _ x _
0h
_ x _ _
INP (In-position) on condition selection
Select a condition that INP (In-position) is turned on.
0: Droop pulses are within the in-position range.
1: The command pulse frequency is 0, and droop pulses are within
the in-position range.
When the position command is not inputted for about 1 ms, the
command pulse frequency is decided as 0.
0h
x _ _ _
For manufacturer setting
0h
Содержание MR-J4-100B(-RJ)
Страница 17: ...8 MEMO ...
Страница 143: ...4 STARTUP 4 20 MEMO ...
Страница 199: ...5 PARAMETERS 5 56 MEMO ...
Страница 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Страница 303: ...9 DIMENSIONS 9 22 MEMO ...
Страница 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Страница 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Страница 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Страница 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Страница 653: ...APPENDIX App 40 This certificate is valid until 2017 02 28 After March 2017 use certificate shown on the previous page ...