11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 81
W ± 0.5
W1
D1
D2
H ±
5
125
D or less
150
4-d mounting hole (Note)
Z
Y T
R X S
(
φ
6 groove)
Fig. 11.11
D or less
4-d mounting hole (Note)
Z
Y T
R X S
H ± 5
180
W ± 0.5
W1
D1
D2
(
φ
8 groove)
Fig. 11.12
Note. Use this for grounding.
Servo amplifier
Power factor
improving AC
reactor
Dimensions
Dimensions
[mm]
Terminal
size
Mass
[kg]
W W1 H
D
(Note)
D1 D2 d
MR-J4-60B4(-RJ) FR-HAL-H1.5K
135
120
115 59
59.6
45 M4 M3.5 1.5
MR-J4-100B4(-RJ) FR-HAL-H2.2K Fig.
11.10 135 120 115 59 59.6 45 M4 M3.5 1.5
MR-J4-200B4(-RJ) FR-HAL-H3.7K
135 120 115 69 70.6 57 M4 M3.5 2.5
MR-J4-350B4(-RJ) FR-HAL-H7.5K
Fig. 11.11
160 145 142 91 91 75 M4 M4
5.0
MR-J4-500B4(-RJ) FR-HAL-H11K
160 145 146 91 91 75 M4 M5 6.0
MR-J4-700B4(-RJ)
MR-J4-11KB4(-RJ)
FR-HAL-H15K
220 200 195 105 90 70 M5 M5
9.0
MR-J4-15KB4(-RJ) FR-HAL-H22K
Fig. 11.12
220 200 215 170 90 70 M5 M8
9.5
MR-J4-22KB4(-RJ) FR-HAL-H30K
220 200 215 170 96 75 M5 M8
11
Note. Maximum dimensions. The dimension varies depending on the input/output lines.
11.13 Relay (recommended)
The following relays should be used with the interfaces
Interface Selection
example
Digital input (interface DI-1)
Relay used for digital input command signals
To prevent defective contacts, use a relay for
small signal (twin contacts).
(Ex.) Omron : type G2A, MY
Digital output (interface DO-1)
Relay used for digital output signals
Small relay with 12 V DC or 24 V DC of rated
current 40 mA or less
(Ex.) Omron : type MY
Содержание MR-J4-100B(-RJ)
Страница 17: ...8 MEMO ...
Страница 143: ...4 STARTUP 4 20 MEMO ...
Страница 199: ...5 PARAMETERS 5 56 MEMO ...
Страница 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Страница 303: ...9 DIMENSIONS 9 22 MEMO ...
Страница 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Страница 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Страница 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Страница 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Страница 653: ...APPENDIX App 40 This certificate is valid until 2017 02 28 After March 2017 use certificate shown on the previous page ...
Страница 654: ...APPENDIX App 41 ...