11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 13
(b) Losses of servo motor and servo amplifier in regenerative mode
The following table lists the efficiencies and other data of the servo motor and servo amplifier in the
regenerative mode.
Servo amplifier
Inverse
efficiency [%]
Capacitor
charging [J]
Servo
amplifier
Inverse
efficiency [%]
Capacitor
charging [J]
MR-J4-10B(-RJ) 55 9
MR-J4-60B4(-RJ) 85 12
MR-J4-20B(-RJ) 75 9
MR-J4-100B4(-RJ)
85 12
MR-J4-40B(-RJ)
85 11
MR-J4-200B4(-RJ)
85 25
MR-J4-60B(-RJ)
85 11
MR-J4-350B4(-RJ)
85 43
MR-J4-70B(-RJ)
85 18
MR-J4-500B4(-RJ)
90 45
MR-J4-100B(-RJ)
85 18
MR-J4-700B4(-RJ)
90 70
MR-J4-200B(-RJ) 85
36
MR-J4-11KB4(-RJ)
90 120
MR-J4-350B(-RJ) 85
40
MR-J4-15KB4(-RJ)
90 170
MR-J4-500B(-RJ) 90
45
MR-J4-22KB4(-RJ)
90 250
MR-J4-700B(-RJ) 90
70
MR-J4-10B1(-RJ) 55
4
MR-J4-11KB(-RJ) 90
120
MR-J4-20B1(-RJ) 75
4
MR-J4-15KB(-RJ) 90
170
MR-J4-40B1(-RJ) 85
10
MR-J4-22KB(-RJ) 90
250
Inverse efficiency (
η
m
): Efficiency including some efficiencies of the servo motor and servo amplifier
when rated (regenerative) torque is generated at rated speed. Efficiency
varies with the speed and generated torque. Since the characteristics of the
electrolytic capacitor change with time, allow for approximately 10% higher
inverse efficiency.
Capacitor charging (Ec): Energy charged into the electrolytic capacitor in the servo amplifier
Subtract the capacitor charging from the result of multiplying the sum total of regenerative energies
by the inverse efficiency to calculate the energy consumed by the regenerative option.
ER [J] =
η
m
• Es - Ec
Calculate the power consumption of the regenerative option on the basis of single-cycle operation
period tf [s] to select the necessary regenerative option.
PR [W] = ER/tf
Содержание MR-J4-100B(-RJ)
Страница 17: ...8 MEMO ...
Страница 143: ...4 STARTUP 4 20 MEMO ...
Страница 199: ...5 PARAMETERS 5 56 MEMO ...
Страница 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Страница 303: ...9 DIMENSIONS 9 22 MEMO ...
Страница 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Страница 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Страница 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Страница 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Страница 653: ...APPENDIX App 40 This certificate is valid until 2017 02 28 After March 2017 use certificate shown on the previous page ...
Страница 654: ...APPENDIX App 41 ...