![background image](http://html.mh-extra.com/html/mitsubishi-electric/mr-j4-100b-rj/mr-j4-100b-rj_instruction-manual_240851338.webp)
11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 19
(4) MR-J4-11KB-PX to MR-J4-22KB-PX/MR-J4-11KB-RZ to MR-J4-22KB-RZ/MR-J4-11KB4-PX to MR-J4-
22KB4-PX/MR-J4-11KB4-RZ to MR-J4-22KB4-RZ (when using the regenerative option)
The MR-J4-11KB-PX to MR-J4-22KB-PX, MR-J4-11KB-RZ to MR-J4-22KB-RZ, MR-J4-11KB4-PX to
MR-J4-22KB4-PX, and MR-J4-11KB4-RZ to MR-J4-22KB4-RZ servo amplifiers are not supplied with
regenerative resistors. When using any of these servo amplifiers, always use the regenerative option
MR-RB5R, MR-RB9F, MR-RB9T, MR-RB5K-4, and MR-RB6K-4.
Cooling the regenerative option with cooling fans improves regenerative capability. G3 and G4 are
thermal sensor's terminals. Between G3 and G4 is opened when the regenerative option overheats
abnormally.
Regenerative option
Configure up a circuit which shuts off main
circuit power when thermal protector operates.
Servo amplifier
C
P+
5 m or less
(Note)
P
C
G3
G4
Note. G3-G4 contact specifications
Maximum voltage: 120 V AC/DC
Maximum current: 0.5 A/4.8 V DC
Maximum capacity: 2.4 VA
Servo amplifier
Regenerative
option
Resistance
[
Ω
]
Regenerative power [W]
Without
cooling fans
With cooling
fans
MR-J4-11KB-PX
MR-J4-11KB-RZ
MR-RB5R 3.2
500
800
MR-J4-15KB-PX
MR-J4-15KB-RZ
MR-RB9F 3
850
1300
MR-J4-22KB-PX
MR-J4-22KB-RZ
MR-RB9T 2.5
850
1300
MR-J4-11KB4-PX
MR-J4-11KB4-RZ
MR-RB5K-4 10 500 800
MR-J4-15KB4-PX
MR-J4-15KB4-RZ
MR-J4-22KB4-PX
MR-J4-22KB4-RZ
MR-RB6K-4 10 850
1300
Содержание MR-J4-100B(-RJ)
Страница 17: ...8 MEMO ...
Страница 143: ...4 STARTUP 4 20 MEMO ...
Страница 199: ...5 PARAMETERS 5 56 MEMO ...
Страница 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Страница 303: ...9 DIMENSIONS 9 22 MEMO ...
Страница 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Страница 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Страница 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Страница 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Страница 653: ...APPENDIX App 40 This certificate is valid until 2017 02 28 After March 2017 use certificate shown on the previous page ...
Страница 654: ...APPENDIX App 41 ...