17. APPLICATION OF FUNCTIONS
17 - 65
(c) Calculation of tolerance against instantaneous power failure
Table 17.10 shows tolerance against instantaneous power failure when instantaneous power failure
voltage is "rated voltage × 50%" and instantaneous power failure time is 200 ms.
Table 17.10 Tolerance against instantaneous power failure
(instantaneous power failure voltage = rated voltage × 50%,
instantaneous power failure time = 200 ms)
Servo amplifier
Instantaneous maximum
output [W]
Tolerance against
instantaneous
power failure [W]
(voltage drop between lines)
MR-J4-10B(-RJ) 350
250
MR-J4-20B(-RJ) 700
420
MR-J4-40B(-RJ) 1400
630
MR-J4-60B(-RJ) 2100
410
MR-J4-70B(-RJ) 2625
1150
MR-J4-100B(-RJ) 3000
1190
MR-J4-200B(-RJ) 5400
2040
MR-J4-350B(-RJ) 10500
2600
MR-J4-500B(-RJ) 15000
4100
MR-J4-700B(-RJ) 21000
5900
MR-J4-11KB(-RJ) 40000
2600
MR-J4-15KB(-RJ) 50000
3500
MR-J4-22KB(-RJ) 56000
4300
MR-J4-60B4(-RJ) 1900
190
MR-J4-100B4(-RJ) 3500
200
MR-J4-200B4(-RJ) 5400
350
MR-J4-350B4(-RJ) 10500
730
MR-J4-500B4(-RJ) 15000
890
MR-J4-700B4(-RJ) 21000
1500
MR-J4-11KB4(-RJ) 40000
2400
MR-J4-15KB4(-RJ) 50000
3200
MR-J4-22KB4(-RJ) 56000
4200
Instantaneous maximum output means power which servo amplifier can output in maximum torque
at rated speed. You can examine margins to compare the values of following conditions and
instantaneous maximum output.
Even if driving at maximum torque with low speed in actual operation, the motor will not drive with
the maximum output. This can be handled as a margin.
The following shows the conditions of tolerance against instantaneous power failure.
1) Delta connection
For the 3-phase (L1/L2/L3) delta connection, an instantaneous power failure occurs in the voltage
between a pair of lines (e.g. between L1 and L2) among voltages between three pairs of lines
(between L1 and L2, L2 and L3, or L3 and L1).
2) Star connection
For the 3-phase (L1/L2/L3/neutral point N) star connection, an instantaneous power failure
occurs in the voltage between a pair of lines (e.g. between L1 and N) among voltages at six
locations, between three pairs of lines (between L1 and L2, L2 and L3, or L3 and L1) and
between one of the lines and the neutral point (between L1 and N, L2 and N, or L3 and N).
Содержание MR-J4-100B(-RJ)
Страница 17: ...8 MEMO ...
Страница 143: ...4 STARTUP 4 20 MEMO ...
Страница 199: ...5 PARAMETERS 5 56 MEMO ...
Страница 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Страница 303: ...9 DIMENSIONS 9 22 MEMO ...
Страница 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Страница 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Страница 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Страница 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Страница 653: ...APPENDIX App 40 This certificate is valid until 2017 02 28 After March 2017 use certificate shown on the previous page ...
Страница 654: ...APPENDIX App 41 ...