11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 37
11.4 FR-RC-(H) power regeneration converter
POINT
When using the FR-RC-(H) power regeneration converter, set [Pr. PA04] to
"0 0 _ _" to enable EM1 (Forced stop 1).
When using the FR-RC-(H) power regeneration converter, refer to "Power
Regeneration Converter FR-RC Instruction Manual (IB(NA)66330)".
When using the FR-RC-(H) power regeneration converter, set [Pr. PA02] to "_ _ 0 1" and set [Pr. PC20] to
"_ _ _ 1".
(1) Selection
The converters can continuously return 75% of the nominal regenerative power. They are applied to the
servo amplifiers of the 5 kW to 22 kW.
Power regeneration
converter
Nominal
regenerative
power [kW]
Servo amplifier
Nominal regenerative power [%]
50
75
100
150
0
500
300
200
100
50
30
20
C
onti
nuous ener
gi
zati
on ti
m
e [s]
FR-RC-15K 15
MR-J4-500B(-RJ)
MR-J4-700B(-RJ)
MR-J4-11KB(-RJ)
MR-J4-15KB(-RJ)
FR-RC-30K 30
FR-RC-55K 55
MR-J4-22KB(-RJ)
FR-RC-H15K 15
MR-J4-500B4(-RJ)
MR-J4-700B4(-RJ)
FR-RC-H30K 30
MR-J4-11KB4(-RJ)
MR-J4-15KB4(-RJ)
FR-RC-H55K 55
MR-J4-22KB4(-RJ)
Содержание MR-J4-100B(-RJ)
Страница 17: ...8 MEMO ...
Страница 143: ...4 STARTUP 4 20 MEMO ...
Страница 199: ...5 PARAMETERS 5 56 MEMO ...
Страница 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Страница 303: ...9 DIMENSIONS 9 22 MEMO ...
Страница 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Страница 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Страница 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Страница 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Страница 653: ...APPENDIX App 40 This certificate is valid until 2017 02 28 After March 2017 use certificate shown on the previous page ...
Страница 654: ...APPENDIX App 41 ...