5. PARAMETERS
5 - 52
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
PF23
OSCL1 Vibration tough drive - Oscillation detection level
This is used to set a filter readjustment sensitivity of [Pr. PB13 Machine resonance
suppression filter 1] and [Pr. PB15 Machine resonance suppression filter 2] while the vibration
tough drive is enabled.
However, setting "0" will be 50%.
Example: When you set "50" to the parameter, the filter will be readjusted at the time of 50%
or more oscillation level.
50
[%]
0 to 100
PF24 *OSCL2 Vibration tough drive function selection
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x
Oscillation detection alarm selection
0: [AL. 54 Oscillation detection] will occur at oscillation detection.
1: [AL. F3.1 Oscillation detection warning] will occur at oscillation
detection.
2: Oscillation detection function disabled
Select alarm or warning when a oscillation continues at a filter
readjustment sensitivity level of [Pr. PF23].
The digit is continuously enabled regardless of the vibration tough
drive in [Pr. PA20].
0h
_ _ x _
For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PF25
CVAT
SEMI-F47 function - Instantaneous power failure detection time
Set the time of the [AL. 10.1 Voltage drop in the control circuit power] occurrence.
This parameter setting range differs depending on the software version of the servo amplifier
as follows.
Software version C0 or later: Setting range 30 ms to 200 ms
Software version C1 or earlier: Setting range 30 ms to 500 ms
To comply with SEMI-F47 standard, it is unnecessary to change the initial value (200 ms).
However, when the instantaneous power failure time exceeds 200 ms, and the instantaneous
power failure voltage is less than 70% of the rated input voltage, the power may be normally
turned off even if a value larger than 200 ms is set in the parameter.
To disable the parameter, select "Disabled (_ 0 _ _)" of "SEMI-F47 function selection" in [Pr.
PA20].
200
[ms]
30 to
500
PF31
FRIC
Machine diagnosis function - Friction judgment speed
Set a (linear) servo motor speed to divide a friction estimation area into high and low for the
friction estimation process of the machine diagnosis.
However, setting "0" will be the value half of the rated speed.
When your operation pattern is under rated speed, we recommend that you set half value to
the maximum speed with this.
Maximum speed in operation
[Pr. PF31] setting
Operation pattern
0 r/min
Servo motor
speed
Forward rotation
direction
Reverse rotation
direction
(0 mm/s)
0
[r/min]/
[mm/s]
0 to
permiss
-ible
speed
Содержание MR-J4-100B(-RJ)
Страница 17: ...8 MEMO ...
Страница 143: ...4 STARTUP 4 20 MEMO ...
Страница 199: ...5 PARAMETERS 5 56 MEMO ...
Страница 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Страница 303: ...9 DIMENSIONS 9 22 MEMO ...
Страница 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Страница 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Страница 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Страница 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Страница 653: ...APPENDIX App 40 This certificate is valid until 2017 02 28 After March 2017 use certificate shown on the previous page ...
Страница 654: ...APPENDIX App 41 ...