17. APPLICATION OF FUNCTIONS
17 - 10
(b) Operation when using a servo amplifier after change of specifications
For the controllers in which "Not required" is described to controller reset in table 17.3, the mode will
be switched to "J3 compatibility mode" for all axes at the first connection. It takes about 10 s for
completing the connection not depending on the number of axes.
For the controllers in which "Reset required" is described in table 17.3, the operation at the first
connection is shown in table 17.4. The servo amplifier's mode will be "J3 compatibility mode" and the
LED displays will be "rST" for all axes at the first connection to the controller as shown in table 17.4.
At the status, resetting controller once will change the display to "b##" (## means axis No.) for all
axes and all axes will be ready to connect.
(One controller reset enables to all-axis connection.)
Table 17.3 Controller reset required/not required list (after change of specifications)
Controller Model
Controller reset required/not required
Single-axis
connection
Multi-axis connection
Motion controller
R_MTCPU
Not required
Not required
Q17_DSCPU
Not required
Not required
Q17_DCPU
Not required
Not required
Q17_HCPU
Not required
Not required
Q170MCPU
Not required
Not required
Simple motion module
Positioning module
RD77MS_
Not required
Not required
QD77MS_
Not required
Not required
LD77MS_
Not required
Not required
QD75MH_
Not required
Not required
QD74MH_
Reset required
Reset required
LD77MH_
Not required
Not required
FX3U-20SSC-H
Reset required
Reset required
Table 17.4 Controller connection operation after change of specifications
After change of specifications (software version A5 or later)
First connection of controller
Controller
Axis
No. 1
S T
r
Axis
No. 2
S T
r
Axis
No. 3
S T
r
"rST" is displayed only for the first connection.
After controller reset
Controller
Axis
No. 1
0 1
b
Axis
No. 2
0 2
b
Axis
No. 3
0 3
b
All axes are connected by one reset.
(c) Using servo amplifiers before and after change of specifications simultaneously
When using servo amplifiers before change of specifications and after change of specifications
simultaneously, controller reset is necessary for number of connecting axes of servo amplifiers.
Содержание MR-J4-100B(-RJ)
Страница 17: ...8 MEMO ...
Страница 143: ...4 STARTUP 4 20 MEMO ...
Страница 199: ...5 PARAMETERS 5 56 MEMO ...
Страница 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Страница 303: ...9 DIMENSIONS 9 22 MEMO ...
Страница 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Страница 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Страница 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Страница 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Страница 653: ...APPENDIX App 40 This certificate is valid until 2017 02 28 After March 2017 use certificate shown on the previous page ...
Страница 654: ...APPENDIX App 41 ...