11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 61
2) Connect the connector for branch cable connection (black) of the new MR-BAT6V1BJ.
MR-BT6VCBL03M
CN4
CN2
Servo amplifier
Old MR-BAT6V1BJ
New MR-BAT6V1BJ
Orange
Orange
Black
3) Remove the connector for servo amplifier (orange) of the old MR-BAT6V1BJ. When the control
circuit power supply is on, performing 3) without [AL. 9F.1 Low battery] will trigger [AL. 9F.1].
MR-BT6VCBL03M
CN4
CN2
Servo amplifier
Old MR-BAT6V1BJ
New MR-BAT6V1BJ
Orange
Orange
Black
4) Remove the old MR-BAT6V1BJ from servo amplifier and mount the new MR-BAT6V1BJ. When
the control circuit power supply is on, [AL. 9F.1] will occur after 3).
MR-BT6VCBL03M
CN4
CN2
Servo amplifier
New MR-BAT6V1BJ
Old MR-BAT6V1BJ
Orange
Orange
Black
Black
5) Mount the connector for servo amplifier (orange) of the new MR-BAT6V1BJ. When the control
circuit power supply is on, [AL. 9F.1] will be canceled.
MR-BT6VCBL03M
CN4
CN2
Servo amplifier
New MR-BAT6V1BJ
Orange
Black
Содержание MR-J4-100B(-RJ)
Страница 17: ...8 MEMO ...
Страница 143: ...4 STARTUP 4 20 MEMO ...
Страница 199: ...5 PARAMETERS 5 56 MEMO ...
Страница 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Страница 303: ...9 DIMENSIONS 9 22 MEMO ...
Страница 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Страница 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Страница 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Страница 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Страница 653: ...APPENDIX App 40 This certificate is valid until 2017 02 28 After March 2017 use certificate shown on the previous page ...
Страница 654: ...APPENDIX App 41 ...