11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 48
(5) Other precautions
(a) When using the FR-CV-(H), always install the dedicated stand-alone reactor (FR-CVL-(H)). Do not
use the power factor improving AC reactor (FR-HAL-(H)) or power factor improving DC reactor (FR-
HEL-(H)).
(b) The inputs/outputs (main circuits) of the FR-CV-(H) and servo amplifiers include high-frequency
components and may provide electromagnetic wave interference to communication equipment (such
as AM radios) used near them. In this case, interference can be reduced by installing the radio noise
filter (FR-BIF(-H)) or line noise filter (FR-BSF01, FR-BLF).
(c) The overall wiring length for connection of the DC power supply between the FR-CV-(H) and servo
amplifiers should be 5 m or less, and the wiring must be twisted.
(6) Specifications
Power regeneration common
converter FR-CV-_
Item
7.5K 11K 15K 22K 30K 37K 55K
Total of connectable servo amplifier
capacities
[kW] 3.75
5.5
7.5
11
15
18.5
27.5
Maximum servo amplifier capacity
[kW]
3.5
5
7
11
15
15
22
Output
Total of connectable servo
motor rated currents
[A]
33 46 61 90 115 145
215
Regenerative
braking torque
Short-time rating
Total capacity of applicable servo motors, 300% torque, 60 s (Note 1)
Continuous rating
100% torque
Power
Rated input AC voltage/frequency
3-phase 200 V AC to 220 V AC, 50 Hz, 200 V AC to 230 V AC, 60 Hz
Permissible AC voltage fluctuation
3-phase 170 V AC to 242 V AC, 50 Hz, 170 V AC to 253 V AC, 60 Hz
Permissible frequency fluctuation
±5%
Power supply capacity
(Note 2)
[kVA]
17 20 28 41 52 66 100
IP rating (JEM 1030), cooling method
Open type (IP00), forced cooling
Environment
Ambient temperature
-10
˚
C to 50
˚
C (non-freezing)
Ambient humidity
5 %RH to 90 %RH (non-condensing)
Ambience
Indoors (no direct sunlight), free from corrosive gas, flammable gas,
oil mist, dust, and dirt
Altitude, vibration resistance
1000 m or less above sea level, 5.9 m/s
2
Molded-case circuit breaker or earth-
leakage current breaker
30AF
30A
50AF
50A
100AF
75A
100AF
100A
125AF
125A
125AF
125A
225AF
175A
Magnetic contactor
S-N20
S-T21
S-N35
S-T35
S-N50
S-T50
S-N65
S-T65
S-N80
S-T80
S-N95
S-T100
S-N125
Содержание MR-J4-100B(-RJ)
Страница 17: ...8 MEMO ...
Страница 143: ...4 STARTUP 4 20 MEMO ...
Страница 199: ...5 PARAMETERS 5 56 MEMO ...
Страница 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Страница 303: ...9 DIMENSIONS 9 22 MEMO ...
Страница 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Страница 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Страница 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Страница 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Страница 653: ...APPENDIX App 40 This certificate is valid until 2017 02 28 After March 2017 use certificate shown on the previous page ...
Страница 654: ...APPENDIX App 41 ...