11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 78
H ± 2.5
W1
W ± 2.5
D2
D1 ± 1
P
P1
D or less
(D3)
4-d mounting hole (Note 1)
6
Fig. 11.6
(Note 2)
Servo amplifier
P3
P4
FR-HEL-H
5 m or less
Note 1. Use this for grounding.
2. When using the power factor improving DC reactor, remove the short bar across P3 and P4.
Servo amplifier
Power factor
improving DC
reactor
Dimensions
Dimensions [mm]
Terminal
size
Mass
[kg]
Wire [mm
2
]
(Note)
W W1 H D D1 D2 D3 d
MR-J4-60B4(-RJ) FR-HEL-H1.5K
Fig. 11.4
66 50
100
80 74 54 37 M4 M3.5 1.0 2
(AWG
14)
MR-J4-100B4(-RJ) FR-HEL-H2.2K
76 50
110
80 74 54 37 M4 M3.5 1.3 2
(AWG
14)
MR-J4-200B4(-RJ) FR-HEL-H3.7K
86 55
120
95 89 69 45 M4 M4 2.3 2
(AWG
14)
MR-J4-350B4(-RJ)
FR-HEL-H7.5K
Fig. 11.5
96 60 128 105 100
80
50
M5
M4
3.5
2 (AWG 14)
MR-J4-500B4(-RJ)
FR-HEL-H11K
105 75 137 110 105
85
53
M5
M5
4.5
3.5 (AWG 12)
MR-J4-700B4(-RJ)
FR-HEL-H15K
Fig. 11.6
105 75 152 125 115 95 62 M5
M6
5.0
5.5 (AWG 10)
MR-J4-11KB4(-RJ)
8 (AWG 8)
MR-J4-15KB4(-RJ) FR-HEL-H22K
133
90
178
120 95 75 53 M5 M6 6.0 8
(AWG
8)
MR-J4-22KB4(-RJ)
FR-HEL-H30K
133 90 178 120 100
80
56
M5
M6
6.5
14 (AWG 6)
Note. Selection conditions of wire size are as follows.
Wire type: 600 V grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction condition: Single wire set in midair
11.12 Power factor improving AC reactors
The following shows the advantages of using power factor improving AC reactor.
It improves the power factor by increasing the form factor of the servo amplifier's input current.
It decreases the power supply capacity.
The input power factor is improved to about 80%.
When using power factor improving reactors for two servo amplifiers or more, be sure to connect a power
factor improving reactor to each servo amplifier. If using only one power factor improving reactor, enough
improvement effect of phase factor cannot be obtained unless all servo amplifiers are operated.
Содержание MR-J4-100B(-RJ)
Страница 17: ...8 MEMO ...
Страница 143: ...4 STARTUP 4 20 MEMO ...
Страница 199: ...5 PARAMETERS 5 56 MEMO ...
Страница 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Страница 303: ...9 DIMENSIONS 9 22 MEMO ...
Страница 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Страница 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Страница 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Страница 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Страница 653: ...APPENDIX App 40 This certificate is valid until 2017 02 28 After March 2017 use certificate shown on the previous page ...
Страница 654: ...APPENDIX App 41 ...