10 OBJECT DICTIONARY
10.1 Object dictionary list
259
10
2B8E
0
Alarm Monitor 14 Load to motor
inertia ratio
The load to motor inertia ratio at
alarm occurrence is returned.
U16
ro
Possible
0000h to
FFFFh
0.01
multiplier
2B8F
0
Alarm Monitor 15 Bus voltage
The bus voltage at alarm
occurrence is returned.
I32
ro
Possible
0000h to
FFFFh
V
2B90
0
Alarm Monitor 16 Load-side
cumulative feedback pulses
The load-side cumulative
feedback pulses at alarm
occurrence are returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
pulse
2B91
0
Alarm Monitor 17 Load-side
droop pulses
The load-side droop pulses at
alarm occurrence are returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
pulse
2B92
0
Alarm Monitor 18 Load-side
encoder information 1 Z-phase
counter
The load-side encoder
information 1 at alarm
occurrence is returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
pulse
2B93
0
Alarm Monitor 19 Load-side
encoder information 2
The load-side encoder
information 2 at alarm
occurrence is returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
pulse
2B97
0
Alarm Monitor 23 Temperature of
motor thermistor
The temperature of motor
thermistor at alarm occurrence is
returned.
I32
ro
Possible
8000h to
7FFFh
°C
2B98
0
Alarm Monitor 24 Motor-side
cumu. feedback pulses (before
gear)
The cumulative feedback pulses
(servo motor-side unit) at alarm
occurrence are returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
pulse
2BA3
0
Alarm Monitor 35 Motor-side/
load-side position deviation
The motor-side/load-side position
deviation at alarm occurrence is
returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
pulse
2BA4
0
Alarm Monitor 36 Motor-side/
load-side speed deviation
The servo motor-side/load-side
speed deviation at alarm
occurrence is returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
pulse
2BA5
0
Alarm Monitor 37 Internal
temperature of encoder
The internal temperature of
encoder at alarm occurrence is
returned.
I32
ro
Possible
8000h to
7FFFh
°C
2BA6
0
Alarm Monitor 38 Settling time
The settling time at alarm
occurrence is returned.
I32
ro
Possible
8000h to
7FFFh
ms
2BA7
0
Alarm Monitor 39 Oscillation
detection frequency
The oscillation detection
frequency at alarm occurrence is
returned.
I32
ro
Possible
8000h to
7FFFh
Hz
Index
Sub
Index
Name and function
Data
Type
Access Variable
mapping
Default
Range
Units
EEP-
ROM
Parameter