9 MANUFACTURER FUNCTIONS
9.5 Simple cam function
211
9
Simple cam specification list
Specification list
*1 The memory capacity includes a use area (storage area for cam data) for storing in the servo amplifier and an actual operation area
(working area for cam data).
Cam resolution
■
Stroke ratio data type
■
Coordinate data type
Item
MR-J4-_GF_-RJ
Memory capacity
Storage area for cam
data
8 Kbytes (Flash-ROM)
Working area for cam
data
8 Kbytes (RAM)
Number of registration
Max. 8
Comment
Max. 32 single-byte characters for each cam data and cam control data
Cam data and cam
control data
Stroke ratio data type
Cam resolution
256/512/1024/2048
Stroke ratio [%]
-100.000 to 100.000
Coordinate data type
Number of coordinate
2 to 1024
Coordinate data
Input value: 0 to 999999
Output value: -999999 to 999999
Cam curve
12 types (constant speed/constant acceleration/5th curve/single
hypotenuse/cycloid/distorted trapezoid/distorted sine/distorted constant
speed/trapecloid/reverse trapecloid/double hypotenuse/reverse double
hypotenuse)
Cam resolution
Max. number of registration
256
8
512
4
1024
2
2048
1
Number of coordinate
Max. number of registration
128
8
256
4
512
2
1024
1