7 PARAMETERS
7.2 Detailed list of parameters
199
7
PN22
**IPOAA
Operation
specification IP
address A
_ _ x x
Operation specification IP address 2
Set the 2nd octet of the IP address of the network device allowed to be connected in hexadecimal.
When both [Pr. PN22] and [Pr. PN23] are set to "0000h", the function is disabled.
When the function is enabled, the servo amplifier allows the following data 1) to 3) to be imported
only if the IP address of the master station (external device) matches with the operation
specification IP address. If they are mismatched, the data is discarded.
1) SDO Download (command 4020h Sub 0002h)
2) SDO Object SubID Block Download (command 4020h Sub 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Setting range: 00h to FFh
00h
x x _ _
Operation specification IP address 1
Set the 1st octet of the IP address of the network device allowed to be connected in hexadecimal.
When both [Pr. PN22] and [Pr. PN23] are set to "0000h", the function is disabled.
When the function is enabled, the servo amplifier allows the following data 1) to 3) to be imported
only if the IP address of the master station (external device) matches with the operation
specification IP address. If they are mismatched, the data is discarded.
1) SDO Download (command 4020h Sub 0002h)
2) SDO Object SubID Block Download (command 4020h Sub 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Setting range: 00h to FFh
00h
PN23
**IPOAB
Operation
specification IP
address B
_ _ x x
Operation specification IP address 4
Set the 4th octet of the IP address of the network device allowed to be connected in hexadecimal.
When both [Pr. PN22] and [Pr. PN23] are set to "0000h", the function is disabled.
When the function is enabled, the servo amplifier allows the following data 1) to 3) to be imported
only if the IP address of the master station (external device) matches with the operation
specification IP address. If they are mismatched, the data is discarded.
1) SDO Download (command 4020h Sub 0002h)
2) SDO Object SubID Block Download (command 4020h Sub 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Setting range: 00h to FFh
00h
x x _ _
Operation specification IP address 3
Set the 3rd octet of the IP address of the network device allowed to be connected in hexadecimal.
When both [Pr. PN22] and [Pr. PN23] are set to "0000h", the function is disabled.
When the function is enabled, the servo amplifier allows the following data 1) to 3) to be imported
only if the IP address of the master station (external device) matches with the operation
specification IP address. If they are mismatched, the data is discarded.
1) SDO Download (command 4020h Sub 0002h)
2) SDO Object SubID Block Download (command 4020h Sub 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Setting range: 00h to FFh
00h
PN24
**IPOR
Operation
specification IP
address range
specification
_ _ x x
Operation specification IP address 4 range specification
Set a value for the 4th octet range of the IP address of the network device allowed to be connected
in hexadecimal.
The range for the IP address of the network device allowed to be connected is between [Pr. PN23 (_
_ x x)] and [Pr. PN24 (_ _ x x)].
Setting "00h" disables the function.
Setting range: 00h to FFh
00h
x x _ _
Operation specification IP address 3 range specification
Set a value for the 3rd octet range of the IP address of the network device allowed to be connected
in hexadecimal.
The range for the IP address of the network device allowed to be connected is between [Pr. PN23 (x
x _ _)] and [Pr. PN24 (x x _ _)].
Setting "00h" disables the function.
Setting range: 00h to FFh
00h
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP
PS