242
9 MANUFACTURER FUNCTIONS
9.5 Simple cam function
Cam standard position restoration
If the cam axis position restoration target is set to "Cam standard position restoration" and bit 5 of Control DI2 (2D02h) turns
on, the "cam standard position" will be restored based on "Cam axis one cycle current value" and "Cam axis feed current
value" and the control is switched to the cam control.
Set the "Cam axis current value per cycle" used for the restoration with cam control data. The feed current value of when bit 5
of Control DI2 (2D02h) is on is used as "Cam axis feed current value".
The following is an example of when restoring the cam standard position to start an operation from a point where both the
feed current value and the cam axis current value per cycle are "0" in the cam whose cam data start position is not "0".
Cam axis one cycle
current value
Cam axis feed current value
Cam standard position
The cam standard position is restored to the cam stroke position that corresponds to
"Feed current value - Cam axis one cycle current value".
0
0
Cam axis one cycle
current value
Cam axis feed current value
(Feed current value)
Cam data
start position
Cam standard position
Cam data