4 STARTUP
4.6 Network setting
55
4
Cyclic communication start
Start the cyclic communication in the following procedure.
Step
Description
Network setting
1.
IP address setting
[IP address setting]
The initial value is 192.168.3.0. To change the initial value, set it with any of
the following. (
• Rotary switches (SW2/SW3)
• Parameters ([Pr. PN11] to [Pr. PN12])
• SLMP communication (IP Address Set command)
2.
Subnet mask setting
[Subnet mask setting]
The initial value is 255.255.255.0. To change the initial value, set it with
either of the following. (
• Parameters ([Pr. PN13] to [Pr. PN14])
• SLMP communication (IP Address Set command)
3.
Slave station (servo
amplifier) power cycling
[Slave station (servo amplifier) power cycling]
The settings of the IP address and subnet mask are reflected.
Communication start procedure
4.
Master station (controller)
cyclic communication start
[Cyclic communication start]
Start the cyclic communication of the master station (controller).
5.
Cyclic communication ready
[Cyclic communication ready]
Set RY (n + 3) F of the master station (controller) to "01h". For the slave
stations (servo amplifiers), start importing the word device (RWw) and set
RX (n + 3) F to "01h".
For the master station (controller), check that RX (n + 3) F is "01h" and read
the word device (RWr).