192
7 PARAMETERS
7.2 Detailed list of parameters
PT42
*OVM
Digital override
minimum
multiplication
Set the minimum speed when the digital override function is enabled.
When you use the digital override function, multiplication can be set with [Pr. PT42] and [Pr. PT43].
Set this and [Pr. PT43] at a time.
Refer to the following table for how to calculate the multiplication value.
Setting "0" will be recognized as "1".
This parameter is available with servo amplifiers with software version A6 or later.
Setting range: 0 to 100
0 [%]
*1 0: Off
1: On
PT43
*OVS
Digital override
pitch width
Set the override pitch when the digital override function is enabled.
When you use the digital override function, multiplication can be set with [Pr. PT42] and [Pr. PT43].
Set this and [Pr. PT42] at a time.
Refer to the table in [Pr. PT42] for settings.
Setting "0" will be recognized as "1".
This parameter is available with servo amplifiers with software version A6 or later.
Setting range: 0 to 20
0 [%]
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP
PS
Input device
*1
Multiplication [%]
OV3/C_OV3 OV2/C_OV2 OV1/C_OV1 OV0/C_OV0
0
0
0
0
Fixed to 100
0
0
0
1
[Pr. PT42]
0
0
1
0
[Pr. PT42] + [Pr. PT43] × 1
0
0
1
1
[Pr. PT42] + [Pr. PT43] × 2
0
1
0
0
[Pr. PT42] + [Pr. PT43] × 3
0
1
0
1
[Pr. PT42] + [Pr. PT43] × 4
0
1
1
0
[Pr. PT42] + [Pr. PT43] × 5
0
1
1
1
[Pr. PT42] + [Pr. PT43] × 6
1
0
0
0
[Pr. PT42] + [Pr. PT43] × 7
1
0
0
1
[Pr. PT42] + [Pr. PT43] × 8
1
0
1
0
[Pr. PT42] + [Pr. PT43] × 9
1
0
1
1
[Pr. PT42] + [Pr. PT43] × 10
1
1
0
0
[Pr. PT42] + [Pr. PT43] × 11
1
1
0
1
[Pr. PT42] + [Pr. PT43] × 12
1
1
1
0
[Pr. PT42] + [Pr. PT43] × 13
1
1
1
1
Fixed to 0