9 MANUFACTURER FUNCTIONS
9.5 Simple cam function
225
9
43
*CLTSMT
Main shaft clutch
smoothing time
constant
This is enabled when [Cam control data 42] is set to "1". Set the smoothing time constant.
Setting range: 0 to 5000
0
[ms]
48
*CCYL
Cam axis length per
cycle
Set an input amount required per cam cycle.
• When [Cam control data No. 30] is set to "0" or "1"
The unit can be changed to 10
STM
[
m], 10
(STM-4)
[inch], 10
-3
[degree], or [pulse] with the
setting of [Pr. PT01].
Feed length multiplication (STM) can be changed with the setting of [Pr. PT03].
• When [Cam control data No. 30] is set to "2"
The unit and feed length multiplication (STM) will be changed to 10
STM
[
m], 10
(STM-4)
[inch], 10
-3
[degree], or [pulse] with the setting of [Cam control data No. 14].
Setting range: 0 to 999999
0
Refer to
Function
column for
unit.
49
*CNO
Cam No.
Set the cam No. of the cam to be executed.
When "0" is set, the selections of remote register RWwnE will be prioritized.
When a value other than "0" is set, the selections of remote register RWwnE will be
disabled.
Setting range: 0 to 8
0
51
*CSTK
Cam stroke amount
Set a cam stroke amount for the stroke ratio of 100% when using the stroke ratio data
type cam.
The unit can be changed to 10
STM
[
m], 10
(STM-4)
[inch], 10
-3
[degree], or [pulse] with the
setting of [Pr. PT01].
Feed length multiplication (STM) can be changed with the setting of [Pr. PT03].
Setting range: -999999 to 999999
0
Refer to
Function
column for
unit.
60
*CPHV
Cam position
compensation
target position
Set a compensation target position to the input axis of the cam axis.
Set the position of the touch probe with the cam axis current value per cycle.
• When [Cam control data No. 30] is set to "1"
The unit can be changed to 10
STM
[
m], 10
(STM-4)
[inch], 10
-3
[degree], or [pulse] with the
setting of [Pr. PT01].
Feed length multiplication (STM) can be changed with the setting of [Pr. PT03].
• When [Cam control data No. 30] is set to "2"
The unit and feed length multiplication (STM) will be changed to 10
STM
[
m], 10
(STM-4)
[inch], 10
-3
[degree], or [pulse] with the setting of [Cam control data No. 14].
Setting range: 0 to [Cam control data No. 48] -1
0
Refer to
Function
column for
unit.
61
*CPHT
Cam position
compensation time
constant
Set the time to apply the position compensation for the input axis of the cam axis.
Setting range: 0 to 65535
0
[ms]
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP
PS