9 MANUFACTURER FUNCTIONS
9.5 Simple cam function
Control of simple cam function
Setting the cam data and the cam control data with MR Configurator2 enables the following three cam controls.
Cam control
method
Description
Actual motion
To-and-fro
control
Reciprocates within
a specified cam
stroke.
Feed control
Updates a cam
standard position
per cycle.
Straight-line
control
Performs straight-
line control to keep
the one-cycle stroke
ratio as 100%.
t
t
Cam data and cam
control data
Cam axis one
cycle current
value (Input)
Cam
conversion
processing
(Cam created by users)
Feed current
value
(Output)
t
t
Cam data and cam
control data
Cam axis one
cycle current
value (Input)
Cam standard
position
(Third cycle)
Cam
conversion
processing
Cam standard
position
(Second cycle)
Cam standard
position
(First cycle)
(Cam created by users)
Feed current
value
(Output)
t
t
Cam data and cam
control data
Cam axis one
cycle current
value (Input)
Cam standard
position
(Third cycle)
Cam
conversion
processing
Cam standard
position
(Second cycle)
Cam standard
position
(First cycle)
(Linear cam: Cam No. 0)
Feed current
value
(Output)
Stroke amount × 100%