22
1 FUNCTIONS AND CONFIGURATION
1.6 Configuration including peripheral equipment
1.6
Configuration including peripheral equipment
• Equipment other than the servo amplifier and servo motor are optional or recommended products.
• When using the MR-J4-_GF-RJ servo amplifier with the DC power input, refer to "MR-J4-_GF_(-RJ) Servo
Amplifier Instruction Manual (Motion Mode)" Appendix 1.
The diagram shows MR-J4-20GF-RJ.
CAUTION
• Connecting a servo motor of the wrong axis to U, V, W, or CN2 of the servo amplifier may cause a malfunction.
CN4
CN5
P+
C
L11
L21
P3
P4
MR Configurator2
CN3
CN8
CN2
CN2L
*4
W
V
U
L1
L2
L3
*1
(MC)
*3
R S T
D
*5
CN1A
CN1B
Power supply
*2
Personal
computer
Molded-case
circuit breaker
(MCCB)
Magnetic
contactor
To safety relay or
MR-J3-D05
safety logic unit
Junction terminal
block
Line noise filter
(FR-BSF01)
Controller or
servo amplifier
Not used
*6
Power factor
improving
DC reactor
(FR-HEL)
Servo motor
Regenerative
options
Battery