4 STARTUP
4.3 Switch setting and display of the servo amplifier
45
4
Status display
Display sequence
*1
*1
*1
*1
Servo amplifier power on
System check in progress
When an alarm No. or warning No. is shown
When [AL. 50 Overload 1] occurs at
identification No. 1
Example:
Ready-off and servo-off
Blinking
After 0.8 s
Ready-on
Blinking
When an alarm or a
warning occurs, the
alarm No. or the
warning No. is shown.
After 0.8 s
Ready-on, servo-off
Blank
Servo-on
When [AL. E1 Overload warning 1]
occurs at identification No. 1
Example:
Blinking
Ready-on, servo-on
After 0.8 s
Blinking
Normal operation
After 0.8 s
Blank
During a warning that does not cause
servo-off, a decimal point on the LED of the
third digit indicates the servo-on status.
Alarm reset or
warning canceled
The segment of the last 2 digits shows the identific
Station
No. 1
Station
No. 2