7 PARAMETERS
7.2 Detailed list of parameters
197
7
Network setting parameters ([Pr. PN_ _])
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP
PS
PN02
CERT
Communication
error detection
time
Set the time until [AL. 86.1 Network communication error 1] is detected.
When "0" is set, the detection time becomes 1000 [ms].
Setting range: 0 to 1000
0 [ms]
PN10
EIC
Ethernet
communication
time-out
selection
Set the time until [AL. 86.4 Network communication error 4] is detected.
Setting "0" will disable the detection of [AL. 86.4 Network communication error 4].
This parameter is enabled with SLMP.
Detection of [AL. 86.4] starts when SLMP is received for the first time. When an alarm is detected
and then reset, the detection stops and will restart upon receipt of the next SLMP.
Setting range: 0 to 60
0 [s]
PN11
**IPADA
IP address
setting A
_ _ x x
IP address setting 2
Set the 2nd octet of the IP address in hexadecimal.
Set the IP address assigned by the network administrator.
When the parameter is set to "_ _ 0 0", the 2nd octet is "168".
When SLMP command (IPAddressSet) is received, the setting of the 2nd octet will be written to this
digit.
Refer to table 7.1 for the relation between the setting value of the rotary switch and the parameter
setting value.
Setting range: 00h to FFh
00h
x x _ _
IP address setting 1
Set the 1st octet of the IP address in hexadecimal.
Set the IP address assigned by the network administrator.
When the parameter is set to "0 0 _ _", the 1st octet is "192".
When SLMP command (IPAddressSet) is received, the setting of the 1st octet will be written to this
digit.
Refer to the table below for the relationship between the rotary switch setting value and the
parameter setting value.
Setting range: 00h to FFh
00h
Relationship between IP address setting and rotary switch
PN12
**IPADB
IP address
setting B
_ _ x x
IP address setting 4
Set the 4th octet of the IP address in hexadecimal.
Set the IP address assigned by the network administrator.
When SLMP command (IPAddressSet) is received, the setting of the 4th octet will be written to this
digit.
Refer to table 7.1 for the relation between the setting value of the rotary switch and the parameter
setting value.
Setting range: 00h to FFh
00h
x x _ _
IP address setting 3
Set the 3rd octet of the IP address in hexadecimal.
Set the IP address assigned by the network administrator.
When the parameter is set to "0 0 _ _", the 3rd octet is "3".
When SLMP command (IPAddressSet) is received, the setting of the 3rd octet will be written to this
digit.
Refer to table 7.1 for the relation between the setting value of the rotary switch and the parameter
setting value.
Setting range: 00h to FFh
00h
Rotary switches
(SW2/SW3)
IP address
1st octet
The setting value of [Pr. PN11 (x x _ _)] is used.
00h
2nd octet
The setting value of [Pr. PN11 (_ _ x x)] is used.
3rd octet
The setting value of [Pr. PN12 (x x _ _)] is used.
4th octet
The setting value of [Pr. PN12 (_ _ x x)] is used.
1st octet
The setting value of [Pr. PN11 (x x _ _)] is used.
01h to FFh
2nd octet
The setting value of [Pr. PN11 (_ _ x x)] is used.
3rd octet
The setting value of [Pr. PN12 (x x _ _)] is used.
4th octet
The setting value of the rotary switches (SW2/SW3) is used.