174
7 PARAMETERS
7.1 Parameter list
Extension setting 2 parameters ([Pr. PE_ _ ])
No.
Symbol
Name
Initial
value
Unit
Detailed
explanation
PE01
**FCT1
Fully closed loop function selection 1
0000h
Motion mode
PE02
For manufacturer setting
0000h
PE03
*FCT2
Fully closed loop function selection 2
0003h
Motion mode
PE04
**FBN
Fully closed loop control - Feedback pulse electronic gear 1 - Numerator
1
PE05
**FBD
Fully closed loop control - Feedback pulse electronic gear 1 -
Denominator
1
PE06
BC1
Fully closed loop control - Speed deviation error detection level
400
[r/min]
PE07
BC2
Fully closed loop control - Position deviation error detection level
100
[kpulse]
PE08
DUF
Fully closed loop dual feedback filter
10
[rad/s]
PE09
For manufacturer setting
0000h
PE10
FCT3
Fully closed loop function selection 3
0000h
Motion mode
PE11
For manufacturer setting
0000h
PE12
0000h
PE13
0000h
PE14
0111h
PE15
20
PE16
0000h
PE17
0000h
PE18
0000h
PE19
0000h
PE20
0000h
PE21
0000h
PE22
0000h
PE23
0000h
PE24
0000h
PE25
0000h
PE26
0000h
PE27
0000h
PE28
0000h
PE29
0000h
PE30
0000h
PE31
0000h
PE32
0000h
PE33
0000h
PE34
**FBN2
Fully closed loop control - Feedback pulse electronic gear 2 - Numerator
1
Motion mode
PE35
**FBD2
Fully closed loop control - Feedback pulse electronic gear 2 -
Denominator
1
PE36
For manufacturer setting
0.0
PE37
0.00
PE38
0.00
PE39
20
PE40
0000h
PE41
EOP3
Function selection E-3
0000h
Motion mode
PE42
For manufacturer setting
0
PE43
0.0