7 PARAMETERS
7.2 Detailed list of parameters
189
7
PT19
*LPPL
Position range
output a
(lower four digits)
Set an address increasing side of the position range output address. The combination of the upper
and lower digits makes one address. Using [Pr. PT19] to [Pr. PT22], set a range in which Index
2D17h Status DO7 bit2 (Position range) turns on.
The unit can be changed to 10
STM
[
μ
m], 10
(STM-4)
[inch], 10
-3
[degree], or [pulse] with the setting of
[Pr. PT01].
The unit [degree] is used with servo amplifiers with software version A6 or later.
Setting range: 8000 0000h to 7FFF FFFFh (-2147483648 to 2147483647)
0000h
Refer to
Function
column
for unit.
PT20
*LPPH
Position range
output a
(upper four digits)
0000h
Refer to
Function
column
for unit.
PT21
*LNPL
Position range
output address -
(lower four digits)
Set an address decreasing side of the position range output address. The combination of the upper
and lower digits makes one address. Using [Pr. PT19] to [Pr. PT22], set a range in which Index
2D17h Status DO7 bit2 (Position range) turns on.
The unit can be changed to 10
STM
[
μ
m], 10
(STM-4)
[inch], 10
-3
[degree], or [pulse] with the setting of
[Pr. PT01].
The unit [degree] is used with servo amplifiers with software version A6 or later.
Setting range: 8000 0000h to 7FFF FFFFh (-2147483648 to 2147483647)
0000h
Refer to
Function
column
for unit.
PT22
*LNPH
Position range
output address -
(upper four digits)
0000h
Refer to
Function
column
for unit.
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP
PS
[Pr. PT19]
[Pr. PT20]
Setting address:
Upper four digits Lower four digits
[Pr. PT21]
[Pr. PT22]
Setting address:
Upper four digits Lower four digits