6 SERVO MOTOR DRIVING
6.3 Indexer mode (idx)
155
6
*1 When the specified station No. exceeds the value set in [Pr. PT28 Number of stations per rotation] - 1, the servo motor does not operate.
*2 "Controlword bit 4 (New set-point)" is not received when the remaining command travel distance is other than "0".
*3 Switching "Profile velocity" during servo motor rotation does not enable this.
*4 Operation is performed as follows.
*5 A delay time can be set with [Pr. PT39].
*6 After power-on, RXn1 turns on if the number of droop pulses is within the in-position range of each station position.
*7 This is enabled when any of Profile velocity (6081h), Profile Acceleration (6083h) or Profile deceleration (6084h) is set to 0.
Operation
(a)
(b)
(c)
Next station No.
No. 1
No. 3
No. 1
Servo motor speed
100.00 r/min
100.00 r/min
150.00 r/min
Positioning
2
1
0
7
6
5
4
3
2
1
0
7
6
5
3
4
2
1
0
7
6
5
4
3