10 OBJECT DICTIONARY
10.2 Object dictionary details (objects in the 1000s)
273
10
10.2
Object dictionary details (objects in the 1000s)
• This section describes the objects in the 1000s. Refer to section 10.1 for details of the objects not listed
here.
Store Parameters (1010h)
• Before shutting off the power supply after executing Store parameters, always check that parameters are
not being saved (bit 0 is on).
For the objects that can be saved, write "65766173h" (= reverse order of the ASCII code of "save") to the corresponding sub
object of Store parameters (1010h) to save the object in the EEP-ROM of the servo amplifier.
The value saved in the EEP-ROM is set to the object at the next power-on. Servo parameters can also be modified through
the object dictionary. However, the new setting is not automatically written to the EEP-ROM. To write the new setting, use
Store parameters (1010h).
Executing Store parameters (1010h) takes about a maximum of 10 s because all parameters are written at the same time. Do
not shut off the power during writing.
Parameter setting values can be saved in EEP-ROM.
Index
Sub Index
Name
Data Type
Access
1010h
0
Store parameters
Number of entries
U8
ro
1
Save all parameters
U32
rw
2
For manufacturer setting
3
4
5