1 FUNCTIONS AND CONFIGURATION
1.6 Configuration including peripheral equipment
23
1
*1 The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used. When not
using the power factor improving DC reactor, short P3 and P4.
*2 For 1-phase 200 V AC to 240 V AC, connect the power supply to L1 and L3. Leave L2 open. For power supply specifications, refer to
section 1.3 of "MR-J4-_GF_(-RJ) Servo Amplifier Instruction Manual (Motion Mode)".
*3 A bus voltage may drop, depending on the main circuit voltage and operation pattern, causing a dynamic brake deceleration during a
forced stop deceleration. When dynamic brake deceleration is not required, delay the time to turn off the magnetic contactor.
*4 This is for MR-J4-_GF-RJ servo amplifier. MR-J4-_GF servo amplifier does not have CN2L connector. When using MR-J4-_GF-RJ
servo amplifier in the linear servo system or in the fully closed loop system, connect an external encoder to this connector. Refer to
section 1.1 of "MR-J4-_GF_(-RJ) Servo Amplifier Instruction Manual (Motion Mode)" and "Linear Encoder Instruction Manual" for the
connectable external encoders.
*5 Be sure to connect between P+ and D terminals. When using a regenerative option, refer to section 11.2 of "MR-J4-_GF_(-RJ) Servo
Amplifier Instruction Manual (Motion Mode)".
*6 CN1B connector is not used during CC-Link IE Field Network Basic communication. Thus, the servo amplifier will not respond if
connected to CN1B connector. Leave this open.