Keysight N9923-90001 User’s Guide
235
System Settings
Service Diagnostics
Service Diagnostics
— The Service diagnostics menu is generally used to display service-related
information. To access these menu items, press
System 7
then
Service
Diagnostics
.
System Information
—
Model Number
– FieldFox model
—
Serial Number
– Identification number of your FieldFox
—
Firmware Release
– The currently installed version of software. Check to
see if you have the latest firmware at:
www.keysight.com/find/fieldfoxsupport
—
Network Identity
– The network name and current IP address of your
FieldFox.
—
Reflectometer Factory Cal
- The Factory (CalReady) Calibration shows the
date and time that the factory cal was performed for each test port and the
Thru connection. The format is P1 <date time>, P2 <date time>, P1-P2
<date time>. The factory calibration is updated when you send your
FieldFox to Keysight for Instrument Calibration. Learn more in
.
Event Log
The Event Log shows the information that has appeared on the FieldFox
screen. The most recent information is at the top of the table.
Press Clear Events to erase this information.
Battery
Chapter 16, “Working with the Lithium-Ion Battery”, on page
.
Internal Temperatures
Learn about the importance of the internal FieldFox temperatures in
High Temperature Protection” on page 24
.
Erase User Data
All data that you have written to the FieldFox can be erased with the press of a
button. You would do this if your FieldFox is located in a secure environment
and must be routinely erased of sensitive data.
Содержание N9923A
Страница 1: ...Keysight Technologies FieldFox RF Network Analyzers N9923A User s Guide ...
Страница 14: ...14 Keysight N9923 90001 User s Guide Contents ...
Страница 20: ...20 Keysight N9923 90001 User s Guide Overview FieldFox Manuals Software and Supplemental Help ...
Страница 36: ...36 Keysight N9923 90001 User s Guide Preparing for Initial Use of Your New FieldFox Connector Care ...
Страница 60: ...60 Keysight N9923 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Страница 100: ...100 Keysight N9923 90001 User s Guide DTF Distance to Fault Measurements DTF Measurement Settings ...
Страница 124: ...124 Keysight N9923 90001 User s Guide Calibration for NA CAT and VVM Modes Calibration Method Summary ...
Страница 134: ...134 Keysight N9923 90001 User s Guide Power Meter USB Mode USB Power Meter Settings ...
Страница 144: ...144 Keysight N9923 90001 User s Guide Frequency Offset Using Power Sensor FOPS Option 208 FOPS Settings ...
Страница 160: ...160 Keysight N9923 90001 User s Guide Pulse Measurements Mode Option 330 Pulse Measurement Settings ...
Страница 206: ...206 Keysight N9923 90001 User s Guide File Management Printing ...
Страница 246: ...246 Keysight N9923 90001 User s Guide Working with the Lithium Ion Battery Lithium Ion Battery Disposal ...
Страница 264: ...264 Keysight N9923 90001 User s Guide Specifications Data Sheet ...
Страница 267: ...267 Keysight N9923A Handheld Analyzer User s Guide D Korean Battery Safety Translation ...
Страница 268: ...268 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Страница 269: ...Keysight N9923 90001 User s Guide 269 Korean Battery Safety Translation ...
Страница 270: ...270 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Страница 275: ...Installation Note Xxxxx xxxxx 3 ...