Maint
08-0420
8.3.19 Replacing sensors (PC11, PC20, PC21L/R, PC41, PC42, PC43, F/L, L/L)
Note: Be sure to attach sensors securely. If a live part of sensor is made a short circuit, it may result in
malfunction.
■ Sensor (Emission) (PC11 sensor)
(1) Remove the Top Cover, Main Cover (L) / (R), and Side Cover (L) / (R). See
“8.1.1 How to remove or attach
the covers”
.
(2) Remove the Input Tray. See
“8.3.6 Replacing Input Tray”
.
(3) Remove the Front Guide assembly. See
“8.1.2 How to remove or attach the guides”
.
(4) Unlock the Cable Clamp, remove 1 bind-head screw (SB306N) fixing the PC11 assembly, and remove the
PC11 assembly.
(5) Disconnect the connector of the Sensor (Emission) (PC11 sensor).
(6) Remove the hook fixing the Sensor (Emission) (PC11 sensor), and remove the Sensor (Emission) (PC11
sensor).
(7) Attach using the above steps in reverse.
PC11 assembly
bind-head screw
(SB306N)
Sensor (Emission) (PC11 sensor)
Connector
clamp
Positioning
bump
Necessary Tools: Phillips Screwdriver (No.2)
Positioning bump
PC11 assembly
hook