Maint
09-0030
● Top Guide Gap
Make sure the Top Guide is Touching the Bump of the Eject Guide and there is no space between them for the
left side of the scanner and space within the range of 0 - 0.2 mm for the right side of the scanner.
If there is a space, loosen the screws for the hook holder, press the Top Unit downward, and fix the screws for
the hook holder.
Take the same step for the opposite side.
After adjusting the gap, apply a small amount of greese to the both shafts of hook holder.
Check point
Should be no space
Hook Holder
Latch Hook
Screws for adjustment
Screw with pressing the
Top Unit downward.
Greese applied part
Check point
Gap 0 - 0.2 mm
Screws for adjustment
Hook Holder
Latch Hook
Greese applied part
Right side view
Left side view
Screw with pressing the
Top Unit downward.