Maint
08-0000
8
Parts Replacement Procedure
(For each diagnostic order for parts replacement, see
“4.2 Diagnostic Order for Parts Replacement“
.
Discard the replaced parts in accordance with the rules and regulations of each municipal.
8.1
Preparation
8.1.1
How to remove or attach the covers
How to remove or attach the covers required for the maintenance work is described.
Caution on electric shock
•
An electric shock may occur. Work after turning OFF the device and removing
the power cable.
Caution on high temperature
•
Some parts may become hot. Work after cooling them down enough.
Top Cover
(1) Remove 4 washer faced head screws (305) fixing the Top Cover.
(2) Operate the Top Latch Button and open the Top Unit.
(3) Slide the Top Cover in the direction A, and then remove the Top Cover by pulling it in the direction B.
(4) Attach the Top Cover using the above steps in reverse.
TOP_COVER
washer faced head
screw (305)
washer faced head screw (305)
washer faced head
screw (305)
washer faced head
screw (305)
Necessary Tools: Phillips screwdriver (No.2)