Maint
08-0620
8.3.24 Replacing Gate Shaft assembly
(1) Remove the Top Cover and Main Cover (L) / (R). See
“8.1.1 How to remove or attach the covers”
.
(2) Remove 1 bind-head screw (SB306N) at the device side fixing the Gate Shaft assembly.
(3) Remove the R SOL assembly from the Gate Shaft assembly.
(4) Remove the E-ring (TW004) and Gate Shaft assembly.
(5) Attach new Gate Shaft assembly.
(6) Insert the groove of the R SOL assembly to the collar and attach the R SOL assembly on the Gate Shaft
assembly.
(7) Fix 1 bind-head screw (SB306N) with pressing the Gate Shaft assembly in the arrow direction (downward).
(8) Attach new E-ring (TW004) and fix the Gate Shaft assembly.
(7) Attach the covers using the above steps in reverse.
Note: Do not use removed E-rings when attaching. Use new ones.
Gate Shaft assembly
bind-head screw
(SB306N)
After removed R SOL assembly
R SOL assembly
collar
groove
Necessary Tools: Phillips Screwdriver (No.2),
E-ring Removal
Needle-nose pliers (For attaching E-ring)
E-ring (TW004)