Maint
08-0430
■ Sensor (Reception) (PC11/PC20 sensor)
(1) Remove the Top Cover and Main Cover (L) / (R). See
“8.1.1 How to remove or attach the covers”
.
(2) Remove the Pick Cover and Pick Unit assembly. See
“8.2.1 Replacing Pick Unit assembly”
.
(3) Remove the Output Tray (Upper) / (Lower). See
“8.3.7 Replacing Output Trays and Output Tray Guide”
.
(4) Remove the Upper Guide assembly. See
“8.1.2 How to remove or attach the guides”
.
(5) Only when replacing the PC 20 sensor, remove the Motor assembly (Pick). See
“8.3.22 Replacing each Motor
assemblies”
.
(6) Remove sensors to be replaced.
- Remove the hook fixing the Sensor (Reception) (PC11 sensor), disconnect the connector, and remove the
Sensor (Reception) (PC11 sensor).
- Remove the hook fixing the Sensor (Reception) (PC20 sensor), disconnect the connector, and remove the
Sensor (Reception) (PC20 sensor).
(7) Attach using the above steps in reverse.
When removed the Pick Motor
Sensor (Reception)
(PC11 sensor)
Sensor (Reception)
(PC20 sensor Reception side)
Motor assembly (Pick)
Necessary Tools: Phillips Screwdriver (No.2)
hook
Sensor (Reception)
(PC11 sensor)
Sensor (Reception)
(PC20 sensor Reception side)
hook