Maint
04-0030
4.3
Replacing Main PCB assembly (CPS878)
(1)
Replacing MAIN PCB assembly Case 1
This is a normal procedure (when you can load the device unique information).
Step
Item
Description
Reference
1
Diagnosis
Load / Store Device Unique
Information
Start mode[1]
Store the device unique information of
the PCB in the host system.
The device unique information includes
scanner model, option information, and
work information.
7.6
Load / Store Device
Unique Information
2
Diagnosis
Option Settings
Start mode[1]
Work Information Display
Start mode[1]
Record the information in the
"Device Unique Information Entry
Sheet".
Option information
Work information
Sheet 04-0070
7.5
Option Settings
7.3
Work Information
Display
3
PCB replacement preparation
Turn off the power.
--
4
Replacing the Main PCB assembly
(CPS878 PCB)
Replace the PCB.
8.3.1
Replacing Main
PCB assembly (CPS878)
5
Preparation after PCB replacement
Turn on the power.
--
6
Diagnosis
Download
Execute this step if a control program
comes with the maintenance part.
If not, this step is not required.
Download the control program to the
Main PCB assembly (CPS878 PCB)
The scanner will be restarted
automatically after the download is
finished.
Wait until the scanner is on standby.
7.4
Download
7
Diagnosis
Load / Store Device Unique
Information
Start mode[2]
Load the device-specific information to
the host system.
The scanner will be restarted
automatically after the loading is
finished.
Wait until the scanner is on standby.
7.6
Load / Store Device
Unique Information
8
Diagnosis
Option Settings
Start mode[1]
Check the loaded device-specific
information.
The information has to be exactly the
same as the information recorded at
Step 2.
7.5
Option Settings
9
User Application
Get the images of test sheet with the
user application and check if there is
noise or abnormality
--
You must keep the "Device Unique Information Entry Sheet
" for the next maintenance work.
[Reason] To support the case where the part of the steps in the above Case (1) cannot be executed.
1. The device unique information cannot be loaded or stored.
2. The device unique information cannot be shown on the option display.
In either of the above cases, work information needs to be entered manually based on estimates. The previous entry
sheet can be used as base data for the estimates.
See replacement procedures "(3) Replacing
Main PCB assembly
Case 3" and "(4) Replacing
Main PCB
assembly
Case 4".
Содержание ImageTracDS 1210
Страница 1: ...Version 1 1 ImageTracDS 1210 1155 Maintenance Manual...
Страница 21: ...Maint 01 0030...
Страница 118: ...Maint 07 0240 The loaded waveform data will be displayed...
Страница 218: ...Maint 10 0020 2 The Menu window of Scanner Utility below is displayed...