Maint
08-0610
8.3.23 Replacing Elevator assembly and Gear (ELE Shaft)
(1) Remove the Top Cover, Main Cover (L) / (R) and Side Cover (L) / (R). See
“8.1.1 How to remove or attach
the covers”
.
(2) Remove the Input Tray. See
“8.3.6 Replacing Input Tray”
.
(3) Remove the Front Guide assembly. See
“8.1.2 How to remove or attach the guides”
.
(4) Remove the E-ring (TW004) for fixing and Gear (ELE Shaft)
(5) Remove the Parallel Pin and E-rings (TW004) at both sides.
(6) Remove the Elevator assembly.
(7) Attach using the above steps in reverse.
Note: Do not use removed E-rings when attaching. Use new ones.
Elevator assembly
Gear (ELE Shaft)
E-ring (TW004) (Step(5))
E-ring (TW004)
for fixing (Step(4))
E-ring (TW004) (Step(5))
Parallel pin
Necessary Tools: Phillips Screwdriver (No.2),
E-ring Removal
Needle-nose pliers (For attaching E-ring)