Maint
08-0500
■ Sensor (Reception) (PC51 sensor)
(1) Remove the Output Tray (Upper). See
“8.3.7 Replacing Output Trays and Output Tray Guide”
.
(2) Slide the cable of the Sensor (Reception) (PC51 sensor), remove 1 washer faced head screw (302) fixing the
Sensor (Reception) (PC51 sensor).
(3) Disconnect the connector.
(4) Attach using the above steps in reverse. Refer the picture below for the cable routing.
■ Sensor (Reception) (PC52sensor)
(1) Remove the Top Cover. See
“8.1.1 How to remove or attach the covers”
.
(2) Remove 1 washer faced head screw (302) fixing the bracket (PC52), and remove the bracket (PC52).
(3) Disconnect the connector of the Sensor (Reception) (PC52sensor).
(4) Remove the hook fixing the Sensor (Reception) (PC52sensor), and remove the Sensor (Reception)
(PC52sensor).
(5) Attach using the above steps in reverse. Fit the hole of the bracket (PC52) to the positioning bump.
Sensor (Reception)
(PC51 sensor)
connector
washer faced head screw (302)
Cable
(Sensor (Reception)
(PC51 sensor))
connector
Sensor (Reception)
(PC52sensor)
hook
Positioning bump
washer faced head
screw (302)
bracket (PC52)
Necessary Tools: Phillips Screwdriver (No.2)
Necessary Tools: Phillips Screwdriver (No.2)
Содержание ImageTracDS 1210
Страница 1: ...Version 1 1 ImageTracDS 1210 1155 Maintenance Manual...
Страница 21: ...Maint 01 0030...
Страница 118: ...Maint 07 0240 The loaded waveform data will be displayed...
Страница 218: ...Maint 10 0020 2 The Menu window of Scanner Utility below is displayed...